Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Language
Document Type
Year range
1.
ACS Meas Sci Au ; 2(6): 620-628, 2022 Dec 21.
Article in English | MEDLINE | ID: covidwho-2245456

ABSTRACT

Rapid antigen tests have become a widely used COVID-19 diagnostic tool with demand accelerating in response to the highly contagious SARS-CoV-2 Omicron variant. Hundreds of such test kits are approved for use worldwide, predominantly reporting on the presence of the viral nucleocapsid (N) protein, yet the comparability among manufacturers remains unclear and the need for reference standards is recognized. To address this lack of standardization, the National Research Council Canada has developed a SARS-CoV-2 nucleocapsid protein reference material solution, NCAP-1. Reference value determination for N protein content was realized by amino acid analysis (AAA) via double isotope dilution liquid chromatography-tandem mass spectrometry (LC-ID-MS/MS) following acid hydrolysis of the protein, in conjunction with UV spectrophotometry based on tryptophan and tyrosine absorbance at 280 nm. The homogeneity of the material was established through spectrophotometric absorbance readings at 280 nm. The molar concentration of the N protein in NCAP-1 was 10.0 ± 1.9 µmol L-1 (k = 2, 95% confidence interval). Reference mass concentration and mass fraction values were subsequently calculated using the protein molecular weight and density of the NCAP-1 solution. Changes to protein higher-order structure, probed by size-exclusion liquid chromatography (LC-SEC) with UV detection, were used to evaluate transportation and storage stabilities. LC-SEC revealed nearly 90% of the N protein in the material is present as a mixture of hexamers and tetramers. The remaining low molecular weight species (<30 kDa) were interrogated by top-down mass spectrometry and determined to be autolysis products homologous to those previously documented for N protein of the original SARS-CoV [Biochem. Biophys. Res. Commun.2008t, 377, 429-433].

2.
ACS measurement science Au ; 2022.
Article in English | EuropePMC | ID: covidwho-2126050

ABSTRACT

Rapid antigen tests have become a widely used COVID-19 diagnostic tool with demand accelerating in response to the highly contagious SARS-CoV-2 Omicron variant. Hundreds of such test kits are approved for use worldwide, predominantly reporting on the presence of the viral nucleocapsid (N) protein, yet the comparability among manufacturers remains unclear and the need for reference standards is recognized. To address this lack of standardization, the National Research Council Canada has developed a SARS-CoV-2 nucleocapsid protein reference material solution, NCAP-1. Reference value determination for N protein content was realized by amino acid analysis (AAA) via double isotope dilution liquid chromatography–tandem mass spectrometry (LC-ID-MS/MS) following acid hydrolysis of the protein, in conjunction with UV spectrophotometry based on tryptophan and tyrosine absorbance at 280 nm. The homogeneity of the material was established through spectrophotometric absorbance readings at 280 nm. The molar concentration of the N protein in NCAP-1 was 10.0 ± 1.9 μmol L–1 (k = 2, 95% confidence interval). Reference mass concentration and mass fraction values were subsequently calculated using the protein molecular weight and density of the NCAP-1 solution. Changes to protein higher-order structure, probed by size-exclusion liquid chromatography (LC-SEC) with UV detection, were used to evaluate transportation and storage stabilities. LC-SEC revealed nearly 90% of the N protein in the material is present as a mixture of hexamers and tetramers. The remaining low molecular weight species (<30 kDa) were interrogated by top-down mass spectrometry and determined to be autolysis products homologous to those previously documented for N protein of the original SARS-CoV [Biochem. Biophys. Res. Commun.2008t, 377, 429−43318926799].

3.
Anal Bioanal Chem ; 414(12): 3561-3569, 2022 May.
Article in English | MEDLINE | ID: covidwho-1733964

ABSTRACT

Development of diagnostic testing capability has advanced with unprecedented pace in response to the COVID-19 pandemic. An undesirable effect of such speed is a lack of standardization, often leading to unreliable test results. To assist the research community surmount this challenge, the National Research Council Canada has prepared a SARS-CoV-2 spike protein reference material, SMT1-1, as a buffered solution. Value assignment was achieved by amino acid analysis (AAA) by double isotope dilution liquid chromatography-tandem mass spectrometry (LC-ID-MS/MS) following acid hydrolysis of the protein, in combination with ultraviolet-visible spectrophotometry (UV-Vis) based on tryptophan and tyrosine absorbance at 280 nm. Homogeneity of the material was established through spectrophotometric absorbance readings at 280 nm. Transportation and long-term storage stabilities were assessed by monitoring relative changes in oligomeric state by size-exclusion liquid chromatography (LC-SEC) with UV detection. The molar concentration of the spike protein in SMT1-1 was 5.68 ± 0.22 µmol L-1 (k = 2, 95% CI), with the native trimeric form accounting for ~ 94% of the relative abundance. Reference mass concentration and mass fraction values were calculated using the protein molecular weight and density of the SMT1-1 solution. The spike protein is highly glycosylated which leads to analyte ambiguity when reporting the more commonly used mass concentration. After glycoprotein molar mass determination by LC-SEC with multi-angle light scattering detection, we thus reported mass concentration values for both the protein-only portion and intact glycoprotein as 0.813 ± 0.030 and 1.050 ± 0.068 mg mL-1 (k = 2), respectively.


Subject(s)
COVID-19 , Spike Glycoprotein, Coronavirus , Glycoproteins , Humans , Pandemics , Reference Standards , SARS-CoV-2 , Tandem Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL